Size |
60 / 70 / 90 / 120 cm |
Controls |
3S+B Touch Control with Display |
Total Absorption |
290 W (90cm) 310W (120W |
Voltage |
220 - 240W |
Lighting |
Halo 2x20 W / 3x20 W (120cm) |
Finishes |
Stainless Steel |
Duct Size |
150mm |
Noise Level |
48-66db(A) |
Booster Airflow |
350-850 m3/h |
Version |
Duct Out |
Energy Class (EU) |
D |
All the technical data are based on manufacturer Italy 🇮🇹 Elica latest catalogues or data sheets, The airflow data is measured by factory lab. at the motor outlet points, it is a Free Motor Blower Value but not the EU testing method with exhaustion tube. All the cooker hoods and appliances specifications are subject to stock model or factory latest update. Please check the final offer from our quotation or offer to confirm the final specifications.
所有技術資料由意大利 Elica 最新產品目錄取得。所有 Elica 油煙機風速量度標準是根據摩打出風口量度並不是歐洲測試加上管導測試標準,所有規格廠方會恆常更新,我們會盡量更新準確資料,客人請參考購買貨物時规格, 貨物規格按現貨規格或訂貨廠方最新更新為準。
ACCESSORIES |
|
Long Life Filter |
F00262/3S |
Charcoal Filter |
F00333/S |
MODEL |
|
TRENDY IX/A/60 |
PRF0027024 |
TRENDY IX/A/90 |
PRF0027022 |
TRENDY IX/A/120 |
PRF0027023 |
|
|
DOWNLOAD
Instruction Menu
Operation
Use the high speed in cases of concentrated kitchen vapors. It is recommended that the cooker hood suction is switched on for 5 minutes prior to cooking and to leave in operation during cooking and for another 15 minutes approximately after terminating cooking.
1. Light ON/OFF
2. Motor ON/OFF
When the key “2” is pressed the motor passes to speed 1. If the key is pressed during working, the hood passes to OFF state.
3. Speed decrease
When key ”3” is pressed the speed decreases from 4 (intense) to 1.
4. Speed increase
When key “4” is pressed with the hood in OFF state, the hood passes to speed 1. If the key is pressed during working, the speed increases from 1 to 4(intense). The intense speed is timed. The standard timing is 5’, at the end of which the hood sets at speed 2. To deactivate the function before the end of the time, press key “3”, the hood sets at speed 3, when key “2” is pressed the hood turn off. A signal on the display corresponds to each speed:
OFF: No Signal
Speed 1: 1
Speed 2: 2
Speed 3: 3
Speed 4: 4 flashing
5. Display
Grease filter signaling
The grease filter is signaled by the display with number 1 flashing after 40 hours of use. This means that the grease filter needs to be washed. The signaling is visible with the hood in ON state. To eliminate the grease filter signaling, press key “2” for more than 3”, until it turns off. The signaling can be eliminated with the hood in ON state.
Carbon filter signaling (only for filtering version)
The carbon filter is signaled by the display with the number 2 flashing after 160 hours of use. This means that the carbon filter installed must be replaced. The signaling is visible with the hood in ON state. To eliminate the carbon filter signaling, press “2” for more than 3”, until it turns off. The signaling can be eliminated with the hood in ON state. In case both filters are signaled at the same time, number 1 and 2 flashes on the display alternately. The signaling can be reset by carrying out the above-described procedure twice. First it resets the grease filter signaling then the carbon filter signaling. In the standard mode the carbon filter signaling is not active. In case the filtering version hood is used, it is necessary to enable the carbon filter signaling.
Activation of carbon filter signaling:
Set the hood to OFF and keep keys “2” and “3” pressed contemporaneously for 3”. Number 1 and 2 flash alternately for 2”.
Deactivation of carbon filter signaling:
Set the hood to OFF and keep keys “2” and “3” pressed contemporaneously for 3”. Number 1 flash alternately for 2”.
Temperature Alarm
The hood is equipped with a temperature sensor which activates the motor at speed 3 in case the temperature in the display zone is too high. The alarm condition is indicated by the display with the letter t flashing. This condition remains as such until the temperature falls below the alarm threshold. This mode can be quite by pressing key “2”, “3”, or “4”. Every 30” the sensor checks the ambient temperature of the display zone.